FCS / SYSTEMS & SOLUTIONSQT520 Series Two-Gas Mixer

Product appearance varies by configuration.

Fluid Control Solutions (FCS)

QT520 Series Two-Gas Mixer

The QT520 Series continuously blends two nonflammable, noncorrosive gases. Motor-driven control and a 32-bit ARM processor regulate the blend. Gas analysis, PID control, data recording, and audible and visual concentration alarms support stable operation. Confirm analyzer type and enclosure rating for your gas combination and installation.

Blend Accuracy
Absolute accuracy ±1%
Input Pressure
0.7-1.0MPa
Output Pressure
0.05-0.4MPa
Maximum Flow
50~400 m³/h
Request a quote

Configuration and suitability confirmed for your application.

Model Specifications (CO₂+Ar Series)

QT520-50-C30ArMaximum Flow (m³/h): 50 Blend Range: 0~30% CO₂, balance argon Buffer Tank Volume (L): 150-W Notes: With analyzer
QT520-100-C30ArMaximum Flow (m³/h): 100 Blend Range: 0~30% CO₂, balance argon Buffer Tank Volume (L): 220-W Notes: With analyzer
QT520-200-C30ArMaximum Flow (m³/h): 200 Blend Range: 0~30% CO₂, balance argon Buffer Tank Volume (L): 470-W Notes: With analyzer
QT520-400-C30ArMaximum Flow (m³/h): 400 Blend Range: 0~30% CO₂, balance argon Buffer Tank Volume (L): 470-W Notes: With analyzer

Model Specifications (O₂+He/Ar Series)

QT520-50-O10ArMaximum Flow (m³/h): 50 Blend Range: O₂ blend; confirm gas composition and range for this configuration Buffer Tank Volume (L): 150-W Notes: With analyzer
QT520-100-O10ArMaximum Flow (m³/h): 100 Blend Range: O₂ blend; confirm gas composition and range for this configuration Buffer Tank Volume (L): 220-W Notes: With analyzer
QT520-200-O10ArMaximum Flow (m³/h): 200 Blend Range: 0~10% O₂, balance argon Buffer Tank Volume (L): 470-W Notes: With analyzer
QT520-400-O10ArMaximum Flow (m³/h): 400 Blend Range: 0~10% O₂, balance argon Buffer Tank Volume (L): 470-W Notes: With analyzer

Model Specifications (H₂+Ar Series)

QT520-50-H10ArMaximum Flow (m³/h): 50 Blend Range: 0~10% H₂, balance argon Buffer Tank Volume (L): 150-W Notes: With analyzer
QT520-100-H10ArMaximum Flow (m³/h): 100 Blend Range: 0~10% H₂, balance argon Buffer Tank Volume (L): 220-W Notes: With analyzer
QT520-200-H10ArMaximum Flow (m³/h): 200 Blend Range: 0~10% H₂, balance argon Buffer Tank Volume (L): 470-W Notes: With analyzer
QT520-400-H10ArMaximum Flow (m³/h): 400 Blend Range: 0~10% H₂, balance argon Buffer Tank Volume (L): 470-W Notes: With analyzer

Model Specifications (H₂+N₂ Series)

QT520-50-H10N2Maximum Flow (m³/h): 50 Blend Range: 0~10% H₂, balance nitrogen Buffer Tank Volume (L): 150-W Notes: With analyzer
QT520-100-H10N2Maximum Flow (m³/h): 100 Blend Range: 0~10% H₂, balance nitrogen Buffer Tank Volume (L): 220-W Notes: With analyzer
QT520-200-H10N2Maximum Flow (m³/h): 200 Blend Range: 0~10% H₂, balance nitrogen Buffer Tank Volume (L): 470-W Notes: With analyzer
QT520-400-H10N2Maximum Flow (m³/h): 400 Blend Range: 0~10% H₂, balance nitrogen Buffer Tank Volume (L): 470-W Notes: With analyzer

Performance Specifications

Blend AccuracyAbsolute accuracy ±1%
Input Pressure0.7~1.0MPa
Output Pressure0.05~0.4MPa
Input Voltage220V/50Hz
Processor32-bit ARM processor
Minimum Actuator Increment0.3μm
Operating ModeAutomatic PLC control / manual adjustment
Control AccuracySelf-tuning PID control
Gas AnalyzerBuilt-in thermal conductivity / zirconia analyzer
Data RecordingDigital recording of concentration trends
Alarm OutputsAudible and visual alarms, RS232 remote output
EnclosureWeather-resistant enclosure; confirm rating for outdoor installation

Measurement conditions & notes

  1. A gas analyzer is standard on models marked -W.
  2. Set the minor component concentration using a single control.
  3. Digital concentration logging supports quality analysis.
  4. Confirm enclosure rating and site conditions before outdoor installation.
  5. Uses a 32-bit ARM processor and a minimum actuator increment of 0.3 μm.
  6. Pressure controllers and solenoid valves regulate system operation.
  7. Confirm the gas composition and blend range for QT520-50-O10Ar and QT520-100-O10Ar with our team before selection.

Confirm fluid compatibility, materials, connections, and available configuration with our team before ordering.