FLOW MEASUREMENT & CONTROLservice@gaskito.com
MFC / GAS FLOWKC200 Series

Product appearance varies by configuration.

Mass Flow Controller (MFC)

KC200 Series

The KC200 Series mass flow controller is designed for equipment integration in semiconductor manufacturing, photovoltaic production, and vacuum coating. EtherCAT and RS-485 versions are available. See the model specifications for wetted materials, seal options, and gas compatibility.

Range
0~10 sccm to 0~400 slm (nitrogen equivalent)
Accuracy
±0.3%F.S. (≤30%F.S.) / ±1.0%S.P. (>30%F.S.)
Turndown Ratio
50:1
Response Time
Controller ≤1s / Meter ≤10ms
Request a quote

Configuration and suitability confirmed for your application.

Basic Parameters

Media RequirementClean, dry gas
Media TypeAir, nitrogen, oxygen, carbon dioxide, hydrogen, methane, ammonia, silane, boron trichloride, chlorine, etc.
Flow Range¹ (Nitrogen Equivalent)(0~10, 20, 50, 100, 200, 500) sccm (0~1, 2, 5, 10, 20, 50) slm (0~100, 200, 400) slm ——Ranges ≥100 slm use external valve structure ——Other ranges available, please contact us
Accuracy±0.3%F.S.² (≤30%F.S.) ——%F.S. means error as percentage of full scale ±1.0%S.P.³ (>30%F.S.) ——%S.P. means error as percentage of setpoint
Turndown Ratio50:1
Response Time⁴Controller: ≤1s Meter: ≤10ms ——Response time refers to time to reach ±2% of setpoint or final stable value
Repeatability≤±0.2%F.S.
Resolution0.01 sccm, ≤100 sccm 1 sccm, >100 sccm
Leak RateFKM seal: ≤4×10⁻¹⁰ Pam³/sHe All-metal seal: ≤1×10⁻¹² Pam³/sHe ——All-metal seal version not available for ranges ≥100 slm
Max Pressure Rating10bar

Environmental Conditions

Operating Temperature0~50℃
Operating Humidity10%~90% R.H. (no condensation)
Working Pressure⁵Controller: max 6 bar (customizable) Meter: 10 bar ——Working pressure refers to differential pressure between inlet and outlet
Storage Temperature-20~85℃

Electrical Parameters

Power SupplyDC24V
Power Consumption≤2.7W
Startup Time≤1s

Communication Interface

EtherCAT VersionRJ45 dual port (with LED), device address 1-999 Configurable via host software or command
RS485 VersionDB9M interface or RJ45 dual port; Modbus-RTU protocol MKS protocol optional; device address 1-99 Baud rate supports 9600, 19200 (default), 38400, etc. Configurable via DIP switch
Analog Signal (RS485 version optional)0-5V or 4-20mA (via DB9M interface)
DisplayEtherCAT version: Yes (located on top) RS485 version: No

Mechanical Parameters

Connector TypeFerrule: 1/4inch, 1/2inch; VCR: 1/4inch, 1/2inch; Others available
Wetted MaterialsFKM seal: 316L stainless steel, fluororubber, silicon nitride All-metal seal: 316L stainless steel ——All-metal seal version not available for ranges ≥100 slm
Body MaterialBase: 316L stainless steel Housing: Aluminum alloy
Seal MaterialFKM fluororubber or all-metal
WeightController: 0.85kg~2.8kg Meter: 0.80kg

Measurement conditions & notes

  1. Unless otherwise specified, this product is calibrated under the following conditions: nitrogen, 25℃, 2.5 bar differential pressure (inlet 3.5 barA, outlet 1 barA), horizontal position.
  2. It is recommended to install a straight pipe section of appropriate size at the inlet, otherwise accuracy deviation may occur.
  3. It is recommended to use the largest possible fittings at the inlet and outlet to avoid additional pressure loss.
  4. The shown ranges are available for nitrogen.
  5. %F.S. means error as percentage of full scale.
  6. %S.P. means error as percentage of setpoint.
  7. Response time refers to time to reach ±2% of setpoint.
  8. Working pressure refers to differential pressure between inlet and outlet.

Confirm fluid compatibility, materials, connections, and available configuration with our team before ordering.